AUSTRALIA · TENDER

Maintenance of Air Conditioning System in Nambucca Valley Council Buildings

The successful Contractor will be required to perform Air Conditioning Maintenance Duties to the cycles nominated in Schedule 3 in Specifications of Works for Nambucca Valley Council. Contractors may also be required to respond to call outs for system/unit failures and will be reimbursed at an agreed rate and agreed response time (information to be provided…

Find your next opportunity

Check scope, work location and the official closing date before shortlisting.

Find similar open tenders

Confirm the actual work location in the procurement documents.

Key facts

Buyer
Nambucca Valley Council
Buyer address
44 Princess St, Macksville, New South Wales 2447, Australia
Status
Closed
Opened
12 Sept 2021
Closed
14 Oct 2021
Decision
27 Oct 2021
Categories
Building Trade, Repairs, Maint.

Summary and scope

The successful Contractor will be required to perform Air Conditioning Maintenance Duties to the cycles nominated in Schedule 3 in Specifications of Works for Nambucca Valley Council. Contractors may also be required to respond to call outs for system/unit failures and will be reimbursed at an agreed rate and agreed response time (information to be provided in the Quotation Form Attachment). General Maintenance Duties for Air Conditioning/Heat Pump Systems Item Maintenance Description 1 Check and clean condenser coils/fan coil units 2 Check and clean drain pan 3 Check and clean condensate drains/tray 4 Leak test all coils and connections 5 Check capacitors 6 Inspect cabinet and for mould growth, remove as required 7 Clean and sanitise evaporator coil for mould and mildew prevention and removal 8 Check and clean air filters 9 Check all supply vents for air circulation 10 Test electrical system (voltage and amps), heating elements, current draw on motors against ratings, controls, capacitors, safety switches, relays, contactors and connections 11 Check crank case heater 12 Check all pumps, reversing valves and auxiliary equipment 13 Check all belts and pulleys for correct operation, undue vibration and rectify 14 Lubricate motor and blower bearings 15 Check for corrosion and treat 16 Check thermostat calibration/set points 17 Check/test refrigerant flow control, pressures and levels 18 Check operating temperatures and drop across coils 19 Clean ceiling cassettes and grilles (can be rotated depending on condition and frequency) 20 Provide report and billing Each system will rely on the manufacturer’s specific recommendations and requirements that the successful tenderer (contractor) will employ to ensure maximum and efficient performance and extended life

Source and freshness

Source update date not provided

Information shown is sourced from public opportunity records. Official buyer documents and addenda take precedence for deadlines, eligibility and submission requirements.